IKEA HB G32 S Mode d'emploi Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
ENGLISH 10
Type of gas used Type of
burner
Injector
marking
Rated
thermal
ow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
(mbar)
min. rat. max.
NATURAL GAS
(Methane)
G20
triple crown
rapid
semi-rapid
auxiliary
132
Y 115
Z 95
X 72
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
2.20
0.60
0.35
0.30
17 20 25
*NATURAL GAS
(Methane)
G25
triple crown
rapid
semi-rapid
auxiliary
144
F3 134
Y 98
F1 77
3.30
3.00
1.65
1.00
365 l/h
332 l/h
183 l/h
111 l/h
2.20
0.60
0.35
0.30
18 20 25
LIQUEFIED
PETROLEUM
GAS
(Butane) G30
(Propane) G31
triple crown
rapid
semi-rapid
auxiliary
81
S 75
M 57
H2 43
3.30
3.00
1.65
1.00
240 g/h
218 g/h
120 g/h
73 g/h
2.25
0.80
0.45
0.40
42.5 50 57.5
Injector table
Category II2H3B/P (AT) II2ELL3B/P (DE)
Type of gas used Model
conguration
5 BURNERS
Rated thermal
owrate (kW)
Total rated
consumption
Air required (m
3
)
for burning1m
3
of gas
G20 20 mbar
3C - 1 R
2 SR - 1 AUX
10.60 1009 l/h 9.52
*G25 25 mbar
3C - 1 R
2 SR - 1 AUX
10.60 1174 l/h 8.187
G30/G31
50 mbar
3C - 1 R
2 SR - 1 AUX
10.60 771 g/h 30.94
Electric Power: 230 V ~ 50 Hz
* Not foreseen for Austria
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 35 36