ENGLISH 10
Type of gas
used
Type of
burner
Injector
marking
Rated
thermal
ow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure
(mbar)
min. rat. max.
NATURAL GAS
(Methane) G25
Rapid
Semi-rapid
Auxiliary
F3 126
Y 91
F1 72
3.00
1.65
1.00
332 l/h
183 l/h
111 l/h
0.60
0.35
0.30
20 25 30
LIQUEFIED
PETROLEUM
GAS
(Butane) G30
(Propane) G31
Rapid
Semi-rapid
Auxiliary
85
63
50
3.00
1.65
1.00
218 g/h
120 g/h
73 g/h
0.60
0.35
0.30
25 30 35
Injector table
Category II2L3B/P
Type of gas
used
Model conguration
4 BURNERS
Rated thermal
ow rate (kW)
Total rated
consumption
Air required
(m
3
) for
burning 1m
3
of gas
G25 25 mbar 1 R - 2 SR - 1 AUX 7.30 809 l/h 8.187
G30/G31 30 mbar 1 R - 2 SR - 1 AUX 7.30 531 g/h 30.94
Electric Power: 230 V ~ 50 Hz